This document describes processing and analytical procedures to assess the potential impact of nanoparticles on plasma coagulation by measuring activated partial thromboplastin time, prothrombin time, and thrombin time using blood collected in sodium citrate tubes. This SOP is a product of the European Nanomedicine Characterisation Laboratory (EUNCL) and is available at: http://www.euncl.org/about-us/assay-cascade/. THE URL SPECIFIED IS A LEGACY WEBSITE. NCI IS NO LONGER IN CONTACT WITH THE SOURCE THAT CONTRIBUTED THIS SOP.