Discard first tube for coagulation testing.
Author(s): Tekkesin N, Esen OB, Kilinç C, Eviyaoglu O
Publication: Blood Coagul Fibrinolysis, 2012, Vol. 23, Page 299-303
PubMed ID: 22450544 PubMed Review Paper? No
Purpose of Paper
Conclusion of Paper
Studies
-
Study Purpose
The purpose of this study was to determine the effects of aliquot sequential collection on PT and APTT using specimens from patients on oral anticoagulant therapy. 2 specimens were consecutively drawn into tubes containing sodium citrate.
Summary of Findings:
Significant differences were found in PT, APTT, and INR between plasma from the first collection and plasma from the second collection. The differences in PT between collection tubes ranged from -15.4% to 18.2%. The differences in APTT between collection tubes ranged from -16.86% to 27.99%. And lastly, the differences in INR between first and second collection tubes ranged from -28.6% to 23.7%, and the difference in INR between the two tubes increased with increasing INR values.
Biospecimens
Preservative Types
- None (Fresh)
Diagnoses:
- Not specified
Platform:
Analyte Technology Platform Morphology Hematology/ auto analyzer Pre-analytical Factors:
Classification Pre-analytical Factor Value(s) Preaquisition Biomarker level INR <2
INR 2.0-3.0
INR 3.1-4.5
INR >4.5
Biospecimen Aliquots and Components Aliquot sequential collection 1st collection
2nd collection