Purpose of Paper

The purpose of this paper was to determine the effects of storage of serum in serum separator tubes (SST) on clinical chemistry analyses.

Conclusion of Paper

Storage of serum for 48 hours in the SST in which specimens were collected and centrifuged had no effects on 86 clinical chemistry determinations when compared with serum that was transferred to a disposable closed culture tube for storage.

Studies

  1. Study Purpose

    The purpose of this study was to determine the effects of refrigerated storage of serum in SST on clinical chemistry analyses.

    Summary of Findings:

    Storage of serum for 48 hours in the SST in which specimens were collected and centrifuged had no clinically significant effects on 86 clinical chemistry determinations when compared with serum that was transferred to a disposable closed culture tube for storage. However, six small but statistically significant (p=0.05) changes were noted including changes in lactate dehydrogenase by SMAC, glucose by SMA 6/60 and AutoAnalyzer I, chloride by colorimetric determination, and lactic acid and lactate dehydrogenase by Dupont ACA. Notably, other methods of detecting these same analytes did not find any statistically significant changes.

    Biospecimens
    Preservative Types
    • Other Preservative
    Diagnoses:
    • Normal
    Platform:
    AnalyteTechnology Platform
    Electrolyte/Metal Clinical chemistry/auto analyzer
    Small molecule Clinical chemistry/auto analyzer
    Carbohydrate Clinical chemistry/auto analyzer
    Steroid Clinical chemistry/auto analyzer
    Protein Clinical chemistry/auto analyzer
    Lipid Clinical chemistry/auto analyzer
    Protein Electrophoresis
    Lipoprotein Electrophoresis
    Electrolyte/Metal Flame emission photometry
    Electrolyte/Metal Colorimetric assay
    Small molecule Radioimmunoassay
    Steroid Radioimmunoassay
    Protein Radial immunodiffusion assay
    Electrolyte/Metal Atomic absorption spectroscopy
    Small molecule GC
    Peptide Radioimmunoassay
    Pre-analytical Factors:
    ClassificationPre-analytical FactorValue(s)
    Storage Type of storage container Serum separator tube
    Closed culture tube
    Clinical chemistry/auto analyzer Specific Technology platform SMAC
    SMA 12/60
    SMA 6/60
    Auto-Analyzer I
    Dupont ACA
    Beckman Microzone System