The purpose of this study was to evaluate whether blood EGF levels were influenced by the type of blood-storage tube. Blood taken in one draw was separated into six different tubes.
Summary of Findings:
EGF peptide levels were dependent upon the type of collection tube used; EGF levels were highest in polystyrene tubes, followed by glass, plastic with clot activator, plastic without clot activator, polypropylene, and plastic tubes with EDTA. EGF levels in blood separated sera differed based upon glass versus polypropylene collection tube, and polystyrene versus vac-gel, vac no-gel, and polypropylene tubes, but not glass versus polystyrene tubes. Plasma separated specimens collected in plastic tubes failed to generate detectable EGF levels. The authors hypothesize that the difference among EGF plasma and serum levels may be due to innate and continuing platelet activity during refrigerated storage.
Biospecimens
Preservative Types
- None (Fresh)
Diagnoses:
- Normal
Platform:
Analyte Technology Platform Peptide ELISA Pre-analytical Factors:
Classification Pre-analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution Round bottom glass tube
Polystyrene tissue culture tube
BD Vacutainer SST II Plus serum separation tube
Plastic Vacuette Z-serum clot activator tube
Plastic Vacuette K2E plasma separtion tube w/ EDTA
Polypropylene with conical bottom
Biospecimen Aliquots and Components Blood and blood products Plasma
Serum
-
Study Purpose
The purpose of this study was to evaluate whether male and female patients had statistically significant differences in serum EGF levels.
Summary of Findings:
Female patients (17 subjects) exhibited statistically significantly higher EGF levels than male (17 subjects) patients. Both sexes displayed similar collection tube dependent trends in EGF levels.
Biospecimens
Preservative Types
- None (Fresh)
Diagnoses:
- Normal
Platform:
Analyte Technology Platform Peptide ELISA Pre-analytical Factors:
Classification Pre-analytical Factor Value(s) Preaquisition Patient gender Female
Male